AMS Nuclear Logo icon

Designed to be mounted on a trolley for ease of movement around site, AMS Nuclear’s mobile samplers couple market leading oxidation efficiency with exceptional build quality to ensure long term reliable service in the capture of Carbon-14, Sulphur-35 and Tritium.

Sometimes referred to as Total Oxidation Units (TOU), these mobile samplers oxidize the sample gas within a reaction tube in a heated environment before flowing through, up to three, bubbler sample bottles. The sample pressure and temperature is displayed along with the mass flow rate and total for data gathering by operators. To enhance longevity, Type N thermocouples are used to control the furnace temperature and provide over-temperature protection.

Total Oxidation Mobile Sampling Unit

Total Oxidation Units (TOU)

At the heart of the TOU is the AMS Nuclear designed and manufactured glass reaction tube. This offers several advantages over other commercially available options such as a reduction in the number of bonded joints to improve its integrity and an increased internal surface area to maximise oxidation and allow combustion temperatures up to 1200°C.

Rigorous testing, witnessed by Magnox plc and approved by British Energy, has proven an oxidation of less than 10ppm when heated above 900°C.

ms Furnace Glass Reactions Tube

Reaction tubes and furnace

Whilst AMS Nuclear’s Total Oxidation Units are usually customised for each client’s specific requirements, they all generally fall into one of three variants depending upon the application.

The Single Stream TOU is used for sampling air in stacks and relies upon sufficient oxygen being present in the sample for combustion to take place. These units are often supplied alongside the static sampling systems used in stack flow monitoring applications.

The Dual Stream TOU is typically employed where the sample gas needs to be supplemented with a separate oxygen feed to enable combustion. Typical applications include the sampling of coolant gas in AGRs to detect a breakthrough of the reactor gas. These units require the sample to be regulated prior to entering the TOU to avoid damaging the glass reaction tube and maintain sampling efficiency.

The High Pressure TOU is very similar to the Dual Stream TOU however this model has on board regulation for applications where the sample can only be supplied at its operating pressure.

The inclusion of thermal mass flow, alarms and data logging capabilities are just some examples of the customisations that can be supplied.

To discuss your sampling needs, please contact us.

Contact Us

TOU Variants

AMS Nuclear carries stock of all consumable parts of the TOU including furnaces, glass reaction tubes, thermocouples and glassware for collecting the samples.

Spares

AMS Nuclear Certifications

ISO 9001:2015
ISO 14001:2015
ISO 45001:2018
Cyber Essentials
Fit For Nuclear