Maintaining the integrity of CO2 distribution systems is essential to safe and reliable nuclear power station operations, particularly where critical isolation functions must remain available following a seismic event. The challenge is enabling operators to isolate affected pipework without relying on access to areas that could become restricted by hot gas release or other environmental hazards.
AMS Nuclear designs and delivers bespoke safety-critical EC&I solutions that address these challenges, combining remote actuation, resilient power supplies and existing plant interfaces to improve operational safety while maintaining established functionality. At Hinkley Point B (EDF Energy), AMS Nuclear delivered a modification to the Fuel Route CO2 isolation valve B/G/90, enabling remote operation from the Central Control Room.
The solution incorporated a bespoke electrical control system, battery-backed power supply and FlexiDrive mechanical actuation arrangement, engineered to support a Category C safety function with Class 3 C&I equipment. By retaining the existing valve and relocating the actuation equipment to a protected area, AMS Nuclear enhanced post-seismic isolation capability while minimising changes to the existing plant infrastructure.